Weather-dependent heating
control with integrated tank
temperature controller and tank
temperature sensor
Electrical auxiliary hea-
ting system E2 / E4,5 / E6
(SE-2-150 to 500)
Electrical
auxiliary heating system
Tank temperature
controller
Electrical connections
14
Control for charging pump / electrical
auxiliary heating system E2 / E4,5 / E6
Insert electronic tank temperature sensor of the heating control into the immersion sleeve
for tank sensors of the floor-standing hot water tank and attach it with sensor holder.
For tanks with sensor channel insert sensor vertically downwards until stop position is
reached.Set desired tank temperature at the tank temperature controller of the heating
control (max. 60°C).
Electrical auxiliary heating system 2 kW/230, 4,5 kW/400 V~, 6 kW/400 V~ VAC with
built-in tank temperature controller and safety temperature limiter.
Screw electrical auxiliary heating system into the pipe coupling at the floor-standing hot
water tank (seal with hemp).
Set desired tank temperature at the tank temperature controller of the heating control
(60°C max).
The connection must be performed by a licensed electrician.
The rules and regulations of the VDE and the local utilities must be observed.
Disconnect power before opening devices.
Unscrew cap from electrical auxiliary heating system and connect system to 230VAC
power supply according to circuit diagram. Connecting wire must be provided on site.
SE-2
3043756_201501