NOTICE!
Carefully insulate and seal off the wall openings after installation to
prevent moisture penetration.
For cooling units with valve couplings
➤ Cut out a hole with a diameter of at least 30 mm (fig. c, page 7) for the cooling
lines. To do this, use a circular cutter.
A
NOTICE!
Never bend the connecting line between the vaporiser and the unit. The
minimum bending radius is 25 mm.
7.3
Installing the cooling unit
It is important to select the proper location for setting up the unit. To ensure trouble-
free operation, please note the following points:
• Set up the cooling unit in a dry, sheltered place. Avoid placing it near heat
sources such as radiators, gas ovens or hot water pipes. Do not place in direct
sunlight.
• On a boat, install the cooling unit, if possible, below the waterline.
• The refrigeration unit functions at a tilt angle of up to 30°. Install the unit on a flat
base so that it will still operate, even at the strongest possible inclination.
• The heated air must dissipate unhindered (fig. d, page 7).
• When installing the cooling unit in a closed room such as a wardrobe, pantry or
aft compartment, openings must have a cross section of at least 200 cm²
(25 cm x 8 cm) for cooling and exhaust air.
• Make sure that the air flow on the condenser (fig. d C, page 7) is not restricted.
• Maintain a minimum distance between the condenser and adjoining wall of
50 mm.