The settings are saved permanently in the internal memory of the device. In the event of a power failure,
the memorized settings are not lost and they are restored when switching on.
Commands
The command SMS should be sent to the cell phone number corresponding to the SIM card inserted in
the device installed.
The format of a command SMS is:
PASSWORD # COMMAND
After executing a command, the device ALWAYS sends an notification SMS to the cell number that sent
the command.
Command
B
Set the bistable mode without Command Notification SMS
BS
Set the bistable mode with Command Notification SMS
Set the pulse mode, with an "x" seconds pulse, without Command
Ix
Notification SMS.
Set the pulse mode, with an "x" seconds pulse, with Command Notifi-
IxS
cation SMS.
T1
Enable the T
T0
Disable the T
Allows to tune the temperature sensor. Before tuning the, please wait
T+xx
until the device reaches full operating temperature (30 minutes at
least).
The device sends a Status Notification SMS to the sender's number
?
containing the output status and information regarding the functions
activated
To add a new enabled User. The number must be in international
A
format, ex. +41335123456789).
To delete an Enabled User.
If the sent number is not listed, the device send an SMS stating "not
D
present" followed by the number.
C
To delete all Enabled Users. It will need about 2 minutes to delete all.
Set the new password, that consists of 4 digits (Ex. from 0000 to
Pxxxx
1234). The device sends an SMS showing the New password.
30
. Notification SMSs will display the temperature.
FUNCTION
.
FUNCTION
Ex. To add 2° C, "T+2", to reduce 3° C, "T-3".
Function
Example
Password 0000
0000#B
0000#BS
0000#I5
0000#I5S
0000#T1
0000#T0
0000#T+02
0000#T-03
0000#?
0000#A+41xxxxxx
0000#D+41xxxxxx
0000#C
0000#P1234