Recommended sauna room ventilation
1. Sauna room
3. Electric sauna heater
2. Washroom
4. Exhaust valve
7. A ventilation valve can be installed here to be kept closed while the sauna is heated and during
bathing.
Inlet vent can be positioned in the A zone. Make sure the incoming fresh air will not interfere with
(i.e. cool down) the sauna heater's thermostat near the ceiling.
The B zone serves as the incoming air zone, if the sauna room isn't fitted with forced ventilation. In
this case, the exhaust valve is installed min 1m higher than the inlet valve.
DO NOT ISTALL INLET VALVE WITHIN ZONE C, IF THE SAUNA HEATER'S CONTROL
THERMOSTAT IS LOCATED AT THE SAME ZONE.
Installing the sensor near a supply air vent
The sauna room air should be exchanged six times in
an hour. The diameter of the supply air pipe should be
between 50 and 100 mm.
A circular air supply vent (360°) must be
installed at least 1000 mm away from the sensor.
An air supply vent with a flow-directing panel
(180°) must be installed at least 500 mm away from the
sensor. Air flow must be directed away from the sensor.
5
7
1
1
4
C
C
C
C
1000 mm
B
B
3
3
5. Exhaust flue or channel
6. Door to the sauna room
1000 mm
360°
500 mm
180°
A
A
A
min
500 mm
1
Sensor
Sensor