We wish you many hours of relaxation and pleasure in your sauna. Please read the instructions beneath very
carefully in order to find out how the sauna works.
ATTENTION: The installation of the sauna heater and other electrical power supply connection should be carried
out by a qualified electrician in accordance with the national electrical code and local regulation.
INSTALLING THE SAUNA HEATER
Before installing the heater, please check the following:
- that the following parts have been delivered: heater, control box with temperature sensor device.
- that the voltage of the heater and control box is correct and that the control box is suitable for the heater
- that the kW of the heater corresponds with the size (m ) of the sauna room. See table 1
- that the minimum construction spaces in fig. 1 are strictly followed
FAILURE TO FOLLOW THE ABOVE INSTRUCTIONS MAY RESULT IN FIRE HAZARD.
The minimum and maximum m
or concrete walls without wooden covering, approx. 1,2m
volume, in order to get the most suitable heater.
MOUNTING THE SAUNA HEATER (See fig 1)
Drill the four screw holes using a 3,5 mm drill bit. The screw head should be approx. 3 mm from the wall surface.
Make sure that the screws are fastened through the sauna room soft wood lining into a backing board to hold
the heater.
Hang the heater on the screws. Tighten the lower screws in order to lock the heater in position.
Re-chech your distances from the heater to combustible materials to make sure the stipulated minimum
distances are followed.
CONTROL PANEL
The control panel is splash proof and may be mounted in the damp area adjacent to the cabin.
SENSOR CONNECTION AND CHECKING
1. The housing for the temperature sensor device, should be attached to the wall as shown in fig. 1. A hole must
be drilled through the wall for the cable, wich should be passed through to the control device.
2. The cable should be carefully attached to the wall to prevent the silicon insulation from being torn.
3. CAREFUL
Connect the sensor cable to the control device as follows:
4. After the completed electrical installation, switch on the equipment. The temperature should be set around the
middle of the scale.
When installing the temperature sensor device, the distances stipulated in fig. 1 must be strictly followed
FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN FIRE HAZARD.
ELECTRICAL HOOK-UP
The wiring diagrams (figs. 2 and 3 ) are to be found in the heater and control box.
The sauna heater MUST NOT be used before firm connection to the electrical system has been established. The
connecting cable must be at least rubber cable. Table 1.
3
depend on the insulation and the surrounding temperature. If the sauna has tile
1 Blue
2 White
3 Red
4 Yellow
Front side
3
2
for every m
of tile or cocncrete must be added to the
Back side