3.4) Signalling LED
Two LEDs (21 and 22) located under the battery in
an easily visible position to the operator provide de-
tails on the operating status of the drilling machine:
RIGHT LED (21) lights up green when the drilling
machine is set for drilling operation (right rota-
tion
).
LEFT LED (22) lights up green when the drilling
machine is set for reverse rotation (left rotation
).
In case the electronic card detects ERRORS or
operational ANOMALIES, the LEDs flashes
with a red light and the machine immediately stops,
refer to § 7 for details.

3.5) OLED Display

The display (13) switches on automatically when the drilling machine
is activated and automatically off in case of non-operation.
The main operational parameters of the drilling machine.
Information on the condition of the drilling machine.
Any operational or procedural alarms (Ref. to § 7).
3.6) Capacitive touch butto
The capacitive touch button (14) for menu selection is placed under
the display and allows selection of various screens (Ref. to § 6) only when the display is on.
The capacitive touch button (14) may not work if touched using objects or when wear-
ing gloves, therefore always operate it using a bare finger.
Do not apply pressure to or stab at the touch button, a light touch using a bare finger is sufficient.
The command pulse is sent when the finger releases the button.