Battery Charging Current Configuration Settings
default
0.5 A
1.0 A
Note:
The VLEVP4 features 4 charging channels. Each channel is independent
and there is no influence to any channel while charging and monitoring
batteries.
Tips
While in charging mode, hold the current button pressed to switch off
the LCD screen.
Choose the most suitable charge current for your batteries:
0.25 A: 10440 - 18700 Li-ion batteries
o
0.5 A: 18650 - 26650 Li-ion batteries with capacity ≥ 2500 mAh
o
1.0 A: Li-ion batteries with capacity ≥ 2000 mAh (1.0 A is the large
o
charging current for fast charging mode)
Remarks
The VLEVP4 has an integrated short-circuit protection to protect the
charger if a short-circuit occurs in a battery. Note that this short-circuit
protection protects the charger and does not prevent batteries from
short-circuiting internally.
The VLEVP4 is only for use with 3.6 V / 3.7 V rechargeable Li-ion
batteries. Charging other battery types may be hazardous, and can
damage the batteries and charger.
The VLEVP4 features battery charging current configure settings. Please
note, that while there is no battery in CH2 and CH3, only CH1 and CH4
can get 1.0 A charging current. As long as there is any battery in CH2
or CH3, the charging current will be 0.5 A for the 4 channels. The
current button can only adjust the charging current to a lower one.
V. 01 – 06/02/2015