DUCTED VERSION
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120mm, the choice of which is left to the installer.
• Install the dumper 10
• Fix the pipe in position using adequate pipe clamps
(not supplied).
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the dumper 10.
• Remove any activated charcoal filters.
RECYCLING VERSION
• Connect the flange to the outlet on the shelf over the
hood using a flexible or rigid pipe (ø120 or 150 mm).
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Ensure that the activated charcoal filters have been
inserted.
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm..