Signal Source; Additional Amplifier; Power Supply And Emergency Power Supply - Monacor PA-900S Mode D'emploi

Masquer les pouces Voir aussi pour PA-900S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
230 V~
50 Hz
FUSE
USE ONLY WITH A 250V FUSE
6 7

5.2 Signal source

As a signal source, connect a unit with a line
output (preamplifier, mixer, PA mixing am-
plifier, etc .) to the XLR input (13) or to the
terminal strip (14) .

5.3 Additional amplifier

If the number of the required speakers is
higher than the number admissible for the
amplifier, an addition al amplifier will be re-
quired . Connect the input of the additional
amplifier to the jack LINE OUT (11) . The out-
put level of the jack depends on the MASTER
VOLUME control (2), however, not on the
tone controls BASS and TREBLE (1) .
5.4 Power supply and
emergency power supply
For continued operation of the amplifier after
a possible mains failure, connect a 24 V emer-
gency power supply unit (e . g . MONACOR
PA-24ESP) to the terminal strip DC INPUT (9) .
To facilitate handling, the terminal strip can be
removed from its plug-in connection .
Finally connect the supplied mains cable
to the mains jack (6) first and then to a mains
socket (230 V/ 50 Hz) .
Notes:
1 . With a voltage of 24 V applied, the amplifier will
be in operation immediately and the LED ON (4)
will light up . It will not be possible to switch off
the amplifier with the POWER switch (5) .
2 . With emergency power supply, the amplifier
will deliver less power than with mains supply .
DC
SPEAKER
INPUT
OUTPUT
GND
24 V
COM
4Ω
70V 100V
8
9
10
6 Operation
1) Prior to switching on the amplifier for the
first time, set the MASTER VOLUME con-
trol (2) to position "0" for the time being .
2) Switch on the amplifier with the POWER
switch (5) . The LED ON (4) will light up .
With an emergency power supply
connected, the LED ON will light perma-
nently and the amplifier will always be in
operation . With the POWER switch, it will
be only possible to switch between mains
supply and emergency power supply in
this case . For normal operation, set the
POWER switch to position "On" . In case of
mains failure, the amplifier will automat-
ically switch to emergency power supply .
3) Set the MASTER VOLUME control (2) to the
desired volume . The 5-step LED VU-meter
(3) will show the output level .
4) Adjust the tone controls BASS and TREBLE
(1) to optimum sound . Readjust the vol-
ume with the MASTER VOLUME control,
if required .
5) In case of unwanted low-frequency inter-
ference (e . g . hum noise), press the button
LOW CUT (12) .
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
LINE OUT
LOW
1
2
CUT
3
11
12
7 Specifications
Rated power
Total music power
Speaker output*
Output LINE OUT
Input
Frequency range
THD
S / N ratio
Tone control
BASS
TREBLE
Power supply
Mains voltage
Power consumption
Emergency power supply
Ambient temperature
Dimensions (W × H × D)
Rack spaces
Weight
*
Either use the 70 V and 100 V outputs or the 4 Ω output!
Subject to technical modification .
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
LINE IN
LINE IN
GND
2
1
3
13
14
PA-900S
120 W
160 W
min. 4 Ω; 70 V/ 100 V
1 V/ 600 Ω
0.765 V/10 kΩ
XLR, balanced
50 Hz – 15 kHz, ±3 dB
< 0.5 % at 120 W
> 80 dB
±10 dB / 100 Hz
±10 dB / 10 kHz
230 V/ 50 Hz
300 VA
24 V (⎓) / 9 A
0 – 40 °C
482 × 88 × 275 mm
2 RS
9.5 kg
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

17.2080

Table des Matières