WIKA P-3 Série Mode D'emploi page 20

Masquer les pouces Voir aussi pour P-3 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Commissioning, operation
Hardware requirement:
Spare USB port
USB adapter cable (order No.: 13193075)
EN
Suitable voltage supply for the pressure sensor
System requirement:
Mircosoft Windows 10 (64 bit)
WIKA software EasyCom 2011 (available for download at www.wika.com)
Fitting of USB adapter cable
1. Switch the pressure sensor to a depressurised state.
2. Remove the clamping nut and carefully pull out the instrument
connector.
3. Connect the spade plug of the USB adapter cable to the instru-
ment's USB connection
4. Connect the USB connector of the adapter cable to the free
USB port of the computer.
5. Connect pressure sensor to power supply.
6.5 Commissioning of USB instruments
For installing the driver, administrator rights are required.
Connect the USB connector with a USB 2.0 port to the computer.
Install the driver via the InstallWizard of the product software.
For further operation the P-3x data logger software is available for download at www.wika.com
(for details see instruction manual P-3x data logger)
Details on the interface protocol or the DLL (Dynamic Link Library) are available for download at
www.wika.com.
All files and documents are available for download at www.wika.com.
20
.
1
WIKA operating instructions pressure transmitter, model P-3x
Mating connector
Sealing
Clamping nut
Instrument connector
Sealing
Case with process
connection
1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P-30P-31

Table des Matières