INSTALLATION
Aspiration unit installation
The aspiration unit can be used in extracting mode or filtering mode (optional active carbon filters
kit or plasma filter kit are available).
Extracting (expulsion to the outside). Kitchen fumes are expelled through the piping (not
supplied with the hood) connected to the motor discharge. The piping must never be connected
to combustion discharge pipes (stoves, boilers, burners, etc.). The use of long pipes, with many
bends, corrugated and with a diameter smaller than the motor outlet's will cause a decrease in
extracting performance and an increase in noise.
Warning! All regulations regarding air exhaust must be observed for installation.
Air should not be discharged into a duct used to discharge exhaust fumes produced by
gas combustion or other fuels (does not apply to hoods used in filtering mode).
Filtering (recycling). The fumes pass through the carbon anti-odour filter (not supplied with the
hood) to be purified and recycled in the kitchen. The use of the carbon anti-odour filter reduces
the hood performance, we therefore recommend the hood is installed in extracting mode.
The figure below is showing how to cut the cabinet base to install the aspiration box (see chapter
'Assemble pieces' number C).
770
290