12. Technical Information
Delivered energy at 50 Ω (Adult Mode) .............................................................................................. Low energy 170J ± 15%
............................................................................................................................................................. High energy 270J ± 15%
Delivered energy at 50 Ω (Paediatric Mode) ........................................................................................ Low energy 50J ± 15%
............................................................................................................................................................... High energy 75J ± 15%
Maximum patient impedance ............................................................................................................................................ 250Ω
Shock sequence ............................................................................... Constant or escalating, programmable (factory setting)
Cycle duration (Analysis and shock preparation) ........................................................................................................................
With fully charged battery ......................................................................................................................................Max. 20 sec.
After 15 shocks .......................................................................................................................................................Max. 24 sec.
After 6 shocks .........................................................................................................................................................Max. 20 sec.
Cycle duration (Switch-on, analysis and shock preparation) ......................................................................................................
With fully charged battery ........................................................................................................................................... < 45 sec.
After 15 shocks ............................................................................................................................................................ < 50 sec.
After 6 shocks .............................................................................................................................................................. < 45 sec.
CPR duration ...............................................................................................................120 sec. (adjustable by factory settings)
ECG ANALYSIS SYSTEM
Duration of analysis .................................................................................................................................................... < 10 sec.
Derivation .................................................................................................................................................................................. II
Impedance measurement .........................................................................................................Controlled by electrode contact
Movement detection ...........................................................................................................................Checks the signal quality
...................................................................................................................................... Acoustic warning at patient movement
Reaction to implanted pacemaker ............................ Normal cardiac pacemaker rhythm is not detected as being shockable.
Asystole threshold .................................................................................................................................................... <0,160 mV
Sensitivity VF / pVT* ........................................................................................................................................................ > %90
Specificity NSR / Asystole* ............................................................................................................................................ > %95
* Report of analysis system can be found in Technical Service Manual, Appendix 1.
OPERATION
Operating elements .............................................Automatic switch-on when the cover is opened, One-button Operation for
................................................................................................. CT0207RS, full-automatic operation for CT0207RF, Info-button
Information Mode ....................................... Announcement of the elapsed time and number of shocks since device started,
........................................................................................................................................................when info-button is pressed
Display Elements ......................................................................... Self-explanatory illuminated symbols (traffic light principle
........................................Device status indicator symbols (OK Symbol, Battery Symbol, Repair Symbol for self-test result)
Acoustic Signals .......................................................................................................................................... Verbal instructions
........................................................................................................................................................... Signal tone (when in use)
.............................................................................................. Signal tone (in stand-by mode for device failure or low battery)
Data Transfer ................................................................................................................... Bluetooth (Only for service provider)
BLUETOOTH
Class ................................................................................................................................................................................ Class 2
Maximum Output .............................................................................................................................................................. 4dBm
Warnings
:
- Medical electrical equipment should be subjected to special precautions regarding EMC. The
following EMC Guidelines must be observed during installation and operation of the device.
- Portable and mobile equipment using RF communications may affect medical electrical
equipments.