Electric Connection - Dexter power AC 06 Traduction Du Manuel D'origine

Table des Matières

Publicité

does not work properly, as described above.
General inspection
1 Regularly check all the fixing bolts for their tight seat.
2 Regularly check, at short intervals, the electric cable
for damages. A damaged cable must be replaced by
an electrician in order to avoid any danger.
Cleaning
1 Always keep the air inputs and outputs free and clean.
2 Regularly remove dust and dirt with a soft brush or a
soft cloth.
3 Regularly grease all moving parts.
4 When the compressor must be cleaned, wipe it with a
soft, moist cloth. A mild rinsing agent may be used, but
no alcohol, gasoline, or another cleaning agent.
5 Never use any caustic agents for cleaning plastic parts.
Attention: Water may never come into contact with
the compressor.
m Electric connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are passed
through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be
used and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does not
hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a cross-
section of 1.5 mm
.
2
Connections and repairs of electrical equipment
may only be carried out by an electrician.
Please provide the following information in the event of
any enquiries:
• Type of current for the motor
• Machine data - type plate
international 23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3906112953

Table des Matières