Remarks for use in potentially explosive atmospheres (ATEX):
• I ffilmofrustispossible(flyingrustintheimmediateproductsurroundings),allouteraluminiumparts
havetobeprotectedaccordingly(e . g . byvarnish) .
• T heproductmustbeelectricallyconnectedtoadequatelyearthedinstallation .
• F orinstallation,removingorrepairoftheproductonsite,onlytoolsallowedforthecorresponding
explosionareacanbeused .
• T heproductshallnotbeexposedto:flames,ionisedradiationandultrasound .
Wedeclare,thattheproduct
Gas pressure regulator 133-..., 233-... and 244-...
isinconformitywiththefollowingdirectives:
1 . 9 7/23/EGmoduleB+DCategory4PressureEquipmentDirective(PED)
mitderEGBaumusterprüfbescheinigung:DVGWCE-0085CM0154 (133)
CE-0085CM0155 (233), CE-0085CM0156 (244)
DVGWCERTGmbH,Zertifizierungsstelle,Josef-Wirmer-Str . 1-3,D-53123Bonn .
T hemoduleDissupervisedbyNotifiedBodyTÜVSüddeutschland,
BauundBetriebGmbH(CE0036)Westendstraße199,D-80686München,Germany .
2 . 2 009/142/EEC(GasAppliancesDirective(30 . 1 1 . 2 009))togetherwithDIN33822&
DINEN334/14382withECtype-examinationcertificate:
DVGWCE-0085CM0154 (133-..)
DVGWCE-0085CM0155 (233-...) and
DVGWCE-0085CM0156 (244-..).
3 . 9 4/9/EG(ATEX)(AnnexVIII),withmarking
Ref. 11501
II 2 G EEx c IIC T5.
T hetechnicaldocumentationhasbeencommunicatedtotheNotifiedBodyL . C . I . E (0081)
33,av . duGénéralLeclerc,92266Fontenay-aux-RosescedexFR
(AcknowledgmentN°LCIE03AR012)
certificateNoEx021048391001
4. F or electrical additional devices only:
89/336/EEC-89(electromagneticcompatibility)withmodificationsunderconsideration
ofthenormsEN50081-2/1993andEN50082-2/1995
CE Certificate of Conformity
ItronGaszählerbauGmbH
76161Karlsruhe
Karlsruhe,14 . 0 6 . 2 011
_____________________
P . Garcia
HeadofProduction
17