Time Mode; Temperature Measurement; Change Of Temperature Unit; Demagnetisation - SKF TIH 200m Mode D'emploi

Appareil de chauffage par induction
Masquer les pouces Voir aussi pour TIH 200m:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
When the selected temperature has been reached, the heater demagnetises the
workpiece, switches off, and generates an acoustic signal for 10 seconds or until
START / STOP is pressed.
Press START / STOP to cancel the acoustic signal and stop the heater.
Remove the workpiece with proper handling equipment.
If the workpiece remains on the heater, the heater will start again when the
temperature of the workpiece drops 10 °C (18 °F).
Press START / STOP to stop the heater and demagnetise the workpiece.
The TIH 220m is now ready to heat another workpiece with the same settings.

5.4 Time Mode

If the remote control display shows °C or °F, press MODE to select TIME MODE.
The remote control display shows 't' in TIME MODE.
Press UP or DOWN to adjust the time in steps of 0,1 minute.
Press POWER to select the power level. Use the guidelines in section 5.8 to
determine the correct power setting.
Press START / STOP to start the heater. The remote control display shows the time
that remains.
During heating, the temperature measured by the probe can be displayed for
a couple of seconds by pressing MODE.
When the time has elapsed, the heater demagnetises the workpiece, switches off,
and generates an acoustic signal for 10 seconds.
Press START / STOP to cancel the acoustic signal and stop the heater.
Remove the workpiece with proper handling equipment.
The TIH 220m is now ready to heat another workpiece with the same settings.

5.5 Temperature measurement

When the heater is not operating, the temperature of the workpiece can be measured
by pressing MODE and START / STOP at the same time. The LED on the
START / STOP button flashes during temperature measurement. Press START / STOP
to cancel temperature measurement.

5.6 Change of temperature unit

Press MODE and UP at the same time to switch between °C and °F.
The temperature unit setting remains the same even after disconnection from mains power.

5.7 Demagnetisation

The workpiece is automatically demagnetised when heating is complete.
Demagnetisation will not occur if the power is interrupted or the main switch is switched
off. To use the TIH 220m for demagnetisation only, select TIME MODE and set the time to
0,1 minute (6 seconds).
SKF TIH 220m
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tih 220m

Table des Matières