Care And Maintenance - Aventics ED05 Rail Notice D'instruction

Régulateur de pression
Masquer les pouces Voir aussi pour ED05 Rail:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AVENTICS | ED05 | R414010201–BAL–001–AA | English
Disassembling the ED05 pressure
regulator
1
1. Stipulate a set point of 0 bar to exhaust the ED05
pressure regulator and the outlet line at outlet
pressure connection 2 (6).
2. Switch off the 24 V DC supply voltage.
3. Remove the connected plugs.
4. Switch-off the supply pressure and exhaust the supply
line.
5. Remove the pneumatic lines.
6. Remove the fastening screws depending on the
mounting type.
Exchange the ED05 pressure regulator
1. Disassemble the ED05 pressure regulator (see
"Disassembling the ED05 pressure regulator").
2. Assemble a new ED05 pressure regulator (see
"Assembly").
9
Disposal
O Dispose of the ED05 pressure regulator in accordance
with the currently applicable regulations in your
country.

10 Care and Maintenance

Dangerous movements
Danger of death, injuries or damage to property!
O Make sure the relevant system component is not
under pressure or voltage before assembling or
when connecting and disconnecting plugs. Protect
the system against being restarted.
O Ensure personnel safety before switching on the
device.
Servicing the ED05 pressure regulator
No special care is required for the ED05 pressure
regulator. Note the following if you would like to clean the
device:
WARNING
Damage to components
Solvents and aggressive detergents will destroy the
surface, labeling and seals of the device!
O Check that all seals and plugs for the plug
connections are firmly fitted so that no humidity can
penetrate the ED05 pressure regulator during
cleaning.
O Only clean the device using a slightly damp cloth.
Only use water to do this and, if necessary, a mild
detergent.
Maintaining the ED05 pressure regulator
In normal ambient conditions
In normal operation, the ED05 pressure regulator is
maintenance-free.
O However, the system-specific maintenance intervals
must be observed.
In aggressive ambient conditions
The seals in the ED05 pressure regulator may age faster
under aggressive ambient conditions.
O Every now and then, check that the seals on the
pressure regulator are in perfect order. A damaged
seal can be recognized by parts of the seal visibly
protruding from the housing gaps. Defective seals will
lead to pneumatic leaks and
non-compliance with the IP54 protection class.
O Immediately exchange the device if the seals are
defective.
NOTICE
20

Publicité

Table des Matières
loading