Technical Data - Harvia SENTIO Just Sauna Fin Instructions D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82
Instructions for installation and use

15. Technical data

Ambient conditions
Storage temperature:
Ambient temperature:
Relative humidity:
Dimensions
Installation cut-out:
Power unit
Operating unit (with installation frame)
Operating unit (without installation frame)
Glass panel for the operating unit
Sauna control unit
Switched voltage/three-phase 3N:
Frequency:
Contact rating/heater:
Switched current per phase/heater:
Contact rating/additional output (dimmable)*
Contact rating/additional output (switchable)*
Switched current/additional output:
Status output:
Rated voltage:
Protection type (protected against jets of water):
Connection to the mains supply as fixed wiring (fixed connection)
* The additional output does not feature an excess temperature fuse. For this reason,
only intrinsically safe devices should be operated using the additional output.
p. 39/40
-25 °C to +70 °C
-10 °C to +40 °C
max. 95%
213 x 82 mm
307 x 175 x 52 mm
222 x 94 x 38 mm
222 x 94 x 31 mm
3.5 mm
400 V AC
50 Hz
3 x 3.5 kW
16 A
500 W
3.5 W
16 A
24 V/200 mA
230 V
IPX4