Preparing For Use; Device Use; Cleaning And Maintenance - UNIPRODO UNI_COOLER_01 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
UNI_COOLER_03
1
6
5
11
3
UNI_COOLER_04
15
1
14
6
12
5
7
11
8
10
3
4
13
1.
Control panel
2.
On / Off button of the heating function
3.
Wheels
4.
Water level indicator
5.
Horizontal jalousies
6.
Vertical jalousies
7.
Inlet of water and ice
8.
Power cord
9.
Internal filter with Honey comb structure
10.
Water tank
11.
External filter
12.
Handle
13.
Water outlet
14.
Ice tank
15.
Top cover

4.2 PREPARING FOR USE

It is necessary to install the attached wheels in the device.
Place the device in a vertical position on a flat and stable
surface. The device is equipped with filters. Before using the
device it is necessary to always make sure whether the filters
are installed in the device. The lack of the external filter
may cause damage to the device by getting contaminants
into its inside. The internal filter enables functioning of the
cooling process and additionally it also filters the air and
moisturizes it (during the cooling process).

4.3 DEVICE USE

Description of control panels and wireless remote controls
10
EN
UNI_COOLER_01
E1
H3
8
B3
D2
B2
D3
C1
F1 B1
F
9
E
B/D
C
H
UNI_COOLER_02
E1
10
D1
B3
D2
B2
D3
C1
F1 B1
F
B
E
D
C
UNI_COOLER_03
9
E1
B
E
G1
A1
C1
B3
F1 H1 H2
D1 D3
B2
F
B1
C
H
G
UNI_COOLER_04
B2
D2
E1
C1
B3
B1
D3
F1
E
C
F
B/D
UNI_
UNI_
UNI_
UNI_
COOLER_01
COOLER_02
COOLER_03
COOLER_04
A
A
F
B
F
F
H
B/D
B/D
F
C
C
G
E
D
E
E
D
E
H
A.
On / off switch
A1. – information on switching the device on / off
B.
Ventilation speed adjustment button
B1. – low ventilation force
B2. – average ventilation force
B3. – strong ventilation force
C.
Button for switching on the automatic movement of
the jalousie
C1. –information on activation of the jalousie
movement function
D.
Ventilation mode selection button
D1. – normal mode
D2. – natural mode
D3. – night mode
E.
Timer
E1. – time of automatic device shutdown
F.
Button for switching on the cooling function
F1. – information on activation of the cooling
function
G.
Button for switching on the air ionization function
G1. – information on activation of the ionization
function
H.
Button for switching on the heating function
H1. – low heating power (UNI_COOLER_03 model)
H2. – high heating power (UNI_COOLER_03 model)
H3. – heating enabled (Model UNI_COOLER_01)
A1
The elements marked with the numbering A1 – H3 are
diodes informing about the activation of a given device
function. If the function is active, the diode lights up,
A
otherwise it is off.
Heating function
The UNI_COOLER_01 AND UNI_COOLER_03 models
have the air heating function.
In the UNI_COOLER_01 model, the function is
activated manually using the button (2), however, it
will work only when the device is switched on (the
A1
On / Off button (1) is on – the diode A1 lights up).
There is only one stage of heating setpoint. If heating
was started manually, it can be operated using the (H)
A
button on the remote control or on the control panel.
Note: Always set the switch (2) to the Off position,
if we turn off the whole device (despite turning
off the device with the remote control, the user
must approach it and turn off the heating function
manually).
The UNI_COOLER_03 model has an automatic
activation of the heating function from the level of
A
the control panel or the wireless remote control. The
heating function has the option of the two-stage
selection of the heating power (change of the stage
A1
by pressing the button (H)). You can disable the
option by pressing the (H) button on the panel or on
A
the wireless remote control.
Cooling function
All models of the devices have the air cooling function.
A
The max. cooling temperature is about 3-5 °C (only
with air humidity <40%). Attention: If the device is
being used in conditions with high temperatures and
B/D
humidity of >40%, the device will not be able to lower
the air temperature.
C
In order to activate the function, the tank of the device
must be filled with water and previously frozen cooling
cartridges or ice cubes. It is forbidden to activate the
function without the tank filled with water.
Topping up the water tank:
In the UNI_COOLER_03, UNI_COOLER_01 and UNI_
COOLER_02 models, it is necessary to pull out the water
tank and fill it with water and frozen cooling cartridges
or ice cubes – this is shown in the picture below:
In the UNI_COOLER_04 model, the water tank is
topped up by pouring clean water and dropping ice
cubes through the inlet hole (7). Note: It is forbidden
to use cooling cartridges in this model! Observe
the level of water being poured on the water level
indicator (4).
Regularly observe the water level in the tank in the
course of the device operation. If necessary, fill up the
water shortages.
EN
11
Setting the operation time
The operating time of the device is set by single pressing the
button (E). Each pressing causes to add 1h starting from 1 to
12h (in the case of the UNI_COOLER_04 model, addition of
0.5h starting from 0.5 to 7.5h).
Operation
Connect the device to the power supply source.
Switch on the device with the On / Off button (A).
Set the device operation manner according to own
preferences. The number of available options from
among the operating modes depends on the device
model.
Single pressings of the option data buttons cause their
activation, the next pressings in case of the buttons
with the single selection causes deactivation of the
given option. In the case of buttons with possibilities
of selection of the functioning option, single pressings
will cause jumping between subsequent options, after
reviewing all options, the next pressing will cause
deactivation of the option.
Depending on the device model, the following options are
available:
1.
COOL/ COOL AIR– cooling option
2.
TIMER – minute timer
3.
MODE – selection of the ventilation mode
4.
SWING – switching on / off the jalousie movement
5.
SPEED – ventilation speed regulation
6.
WARM – heating option
7.
IONIZER – switching on / off the ionization function
The user has the possibility to manually set the
ventilation
angle
(manually
setting
jalousies).
In case of operating the device with a remote control,
it is necessary to direct the remote control transmitter
towards the device.
Always turn off the device after the end of its use.
It is best to disconnect the device from the power
supply source.
In case of moving the device to another location, it
is necessary to use the handles if they are installed
in the device and the wheels. The water tank must
be emptied for the period of transport. Transport the
device only and exclusively in the vertical position.

4.4 CLEANING AND MAINTENANCE

Before cleaning, maintenance and when not in use,
make sure the power cable is disconnected and the
device has cooled down.
Use cleaners without corrosive substances to clean
each surface.
Clean the device with a soft cloth. It is forbidden to
pour water on the device.
Regularly clean the filters installed in the device.
Cleaning the external and internal filter:
Dismantle the external filter by unscrewing it from the back
part of the device housing. Dismantling the external filter
(11) will enable access to the internal filter with a honey
comb structure (9).
9
11
horizontal

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Uni_cooler_02Uni_cooler_03Uni_cooler_04

Table des Matières