Technical Data - Abus Secvest FUSG50101 Instructions D'installation Et D'utilisation

Masquer les pouces Voir aussi pour Secvest FUSG50101:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 56

Technical data

Technical data
Product name
Product description
Item no.
Manufacturer
Environmental class
Protection class,
IP protection class
Operating temperature
Storage temperature
Humidity, max.
Housing material
Dimensions (W x H x D)
Weight
Security level
Tamper protection
(detection/protection)
Flashing frequency
34 |
EN
Secvest Wireless Outdoor Sounder
Signal generator
FUSG50101
ABUS Security-Center GmbH & Co. KG
IV (EN 50131-1:2006+A1:2009+ A2:2017 Section 7.4; except
Denmark, Finland, Norway and Sweden according to Annex A)
IP65 (in installed state)
IP = international protection or ingress protection
6 = complete protection against contact
5 = protection from jets of water (from a nozzle) from any angle
-25 °C to +60 °C
-10 °C to 40 °C
max. 95 %
Polycarbonate
210.6 x 294 x 78.5 mm
1.2 kg (without batteries)
2.6 kg with batteries
2 x 0.7 kg batteries alone (0.7 kg per battery pack)
Grade 2 (EN 50131-1:2006+A1:2009+ A2:2017 Section 6)
Type B (EN 50131-3:2009 Section 8.7)
Double flash @ approx. 1 Hz