Signal generation
Sound pressure
Tones
Maximum duration of the
acoustic alarm
Power supply type
Type of power supply
Power consumption/
energy consumption
Normal voltage
Battery type
Battery life
Standby time of the
energy storage system
Battery
undervoltage threshold
Integrated piezo sounder
>= 100 dB(A) @ 1 m
2 x normal alarm, fire alarm, perimeter warning, acknowledgement
beep
15 minutes
Cable type W (EN 50131-4:2010 Section 5.6.3.2)
Type C with reference to EN 50131-1:2006+A1:2009+ A2:2017
Section 9 and
EN 50131-6 Section 4.1
Standby current including comfort LEDs
0.25 mA
Siren sounding alarm
225 mA
6 V DC
2 x 3 V alkaline manganese batteries, 18 Ah
Item number of the replacement batteries: FU2986 (comprises
2 battery packs)
2 years nominal
With one activation per month for 3 minutes.
Flashing and audio alarm
With one arming acknowledgement per day.
Acknowledgement flash and beep
With one disarming acknowledgement per day.
Acknowledgement flash and beep
Type W (EN 50131-4:2009 Section 5.6.3.2) for battery operation
only, without external power supply via power supply unit.
4.5 V
"Flat battery" fault at <4.5 V
Technical data