Electrical Installation - Vetus TMWQ 12 V Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20

4.6 Electrical installation

• Check that the voltage given on the type plate on the motor is the
same as the voltage on board.
Use batteries with sufficient power to guarantee that the toilet
will work correctly.
• Connect the power supply as shown in the wiring diagram. Fit a
switch and a fuse in the ('+') wire.
Use wires with minimum cross section of 6 mm
12 V) or 4  mm
2
(AWG12) (for 24 V).
4.7 Fitting the toilet to the floor
• Attach the toilet using the fasteners supplied.
Do not overtighten.
10
110136.04
2
(AWG10) (for
W
arning
4.8 Testing
• Switch on the main switch.
• Open the ball valve in the water supply pipe completely so that
there will be a sufficient supply of water for flushing.
Do not forget to open the shut-off valve in the outlet (if present).
• Press the 'NORMAL' button once and check
whether the cycle is carried out properly.
• Throw a few pieces of toilet paper into the bowl
and check the cycle again.
• Check that there are no leaks at any of the connections.
• Press 'ADD WATER' until the water lev-
el in the toilet bowl is about halfway
(about 9 sec).
• Throw a few pieces of toilet paper in
the toilet bowl and press 'PUMP OUT'
(about 6 sec) to pump the toilet emp-
ty.
• Press 'ADD WATER' to fill the bottom
of the toilet bowl with water (about 4
sec).
The times given can be used as refer-
ence times to check that the toilet is
working properly.
• Check that there are no leaks at any of the connections.
TMWBP
TMWBS
ADD WATER
PUMP OUT
ADD WATER
vetus® Electric Marine Toilets TM series

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tmwq 24 vTmwbpTmwbsTm sérieTmw24qTmw12q ... Afficher tout

Table des Matières