recovery of refrigerant). Cylinders shall be complete with
pressure relief valve and associated shut-off valves in good
working order. Empty recovery cylinders are evacuated and, if
possible, cooled before recovery occurs. The recovery
equipment shall be in good working order with a set of
instructions concerning the equipment that is at hand and shall
be suitable for the recovery of flammable refrigerants. In
addition, a set of calibrated weighing scales shall be available
and in good working order. Hoses shall be complete with leak-
free disconnect couplings and in good condition. Before using
the recovery machine, check that it is in satisfactory working
order, has been properly maintained and that any associated
electrical components are sealed to prevent ignition in the event
of a refrigerant release. Consult manufacturer if in doubt. The
recovered refrigerant shall be returned to the refrigerant supplier
in the correct recovery cylinder, and the relevant Waste Transfer
Note arranged. Do not mix refrigerants in recovery units and
especially not in cylinders. If compressors or compressor oils
are to be removed, ensure that they have been evacuated to an
acceptable level to make certain that flammable refrigerant does
not remain within the lubricant. The evacuation process shall be
carried out prior to returning the compressor to the suppliers.
Only electric heating to the compressor body shall be employed
to accelerate this process. When oil is drained from a system, it
shall be carried out safely.
Fuse parameters of the machine
Type: 5ET or SMT
Unit Storage:
1. Unscrew the drainage cover, unplug the water plug, and
discharge the water in the water pan into other water containers
or directly tilt the body to discharge the water into other
containers.
2. Turn on the machine, adjust it to low-wind ventilation mode, and
maintain this state until the drainage pipe becomes dry, so as to
keep the inside of the body in a dry state and prevent it from
mildewing.
3. Turn off the machine, unplug the power plug, and wrap the
power cord around the wrapping post; install the water plug and
the drainage cover.
4. Remove the exhaust pipe and keep it properly.
Voltage: 250V Current: 3.15 A