Use a screwdriver on the water level adjustment screw (see Fig. 1) to move the contact
directly on the grid assembly.
 Turn the screw clockwise
 Turn the screw anticlockwise
A full turn (360°) will fill with 40 cm³ water (~2.4 sec.)
A half turn (180°) will fill with 20 cm³ water (~1.2 sec.)
PRODUCTION
The base of the grid assembly is filled with water and the
thermostat remains in the open position.
EJECTION
Once at the correct temperature, the thermostat will close, enabling
1
the heating element and the motor.
The extractor blades will press on the ice until it detaches; the heating
2
element remains enabled.
The blades extract the ice cubes from their seating, pouring them into
3
the tray (B).
During maintenance operations, the ice-making operations are interrupted.
Maintenance will begin when:
There is no water. To restart ice production, fill the tank.
The tray is full of ice. To restart the ice-making process, it is sufficient to empty the
tray (even partially).
to reduce the quantity of water
to increase the quantity of water