ATTACHING THE MISTING RING TO THE FAN
COVER
See Figures 13 - 15.
 Loosen height adjusting knob and adjust stand to desired
height. Tighten securely.
 Align the clips onto the wires of the front fan cover
pressing the clips in the positions as shown in figure 13.
 With the misting tube facing down, push the misting ring
onto the clips (see figure 14).
 Hold the misting tube secure against the stand pole using
the two clips (see figure 15).
WARNING:
Do not allow familiarity with products to make you
careless. Remember that a careless fraction of a second
is sufficient to inflict serious injury.
WARNING:
Keep water and mist discharge pointed away from all
electrical devices to reduce the risk of electrocution or
electric shock.
WARNING:
Do not use any attachments or accessories not
recommended by the manufacturer of this product. The
use of attachments or accessories not recommended
can result in serious personal injury.
APPLICATIONS
You may use this product for the following purposes:
 Outdoor cooling
WARNING:
Do not use this misting fan to spray pesticides, liquid
fertilizers, chemicals or any liquids other than clean water.
Spraying these substances could result in serious injury
or illness to the operator or bystanders.
ASSEMBLY
CONNECTING THE GARDEN HOSE
See Figures 16 - 17.
 Completely uncoil the garden hose to prevent kinks.
 Run water through the hose for 30 seconds to clean any
debris from the hose.
 With the faucet turned completely off, attach the end of
the garden hose to the misting tube coupler. Tighten by
hand.

OPERATION

GROUND FAULT CIRCUIT INTERRUPTER
See Figure 3.
This unit is equipped with a Ground Fault Circuit Interrupter
(GFCI), which guards against the hazards of ground fault
currents. An example of ground fault current is the current
that would flow through a person who is using an appliance
with faulty insulation and, at the same time, is in contact
with an electrical ground such as a plumbing fixture, wet
floor, or earth.
GFCI receptacles do not protect against short circuits,
overloads, or shocks.
NOTE: To ensure readiness for use, press the reset button
each time you connect the tool to the power supply.
The GFCI receptacles can be tested with the TEST and
RESET buttons.
To test:
 Depress the TEST button. This should cause the RESET
button to pop out.
 To restore power, depress the RESET button.
Perform this test monthly to ensure proper operation of the
GFCI.
WARNING:
To reduce the risk of electrocution, keep all connections
dry and off the ground. Do not touch the plug with wet
hands.
6 — English