Setting
Function
range
S
0 ... 3
Miscellaneous
.
Settings
Display version
i
.
information
15

Causes of faults

The following can be the causes of faults for incorrect reactions of the motion detector:
moving parts in the sector
-
vibrations which are transferred to the device via the mounting bracket
-
electrical faults via the connection cable
-
electric fields (radio)
-
fluorescent or gas discharge lamps in the detection area
-
reflection of the radar rays on conductive floors or walls
-
FEIG ELECTRONIC GmbH
Manual
Description / note
The LED display and the buttons on the case can be
deactivated with this parameter.
0: buttons and display off
1: buttons activated, display off
2: only display activated
3: buttons and display on
Irrespective of this parameter setting, it is always
possible to operate the MWD BP using the buttons within the
first 15 minutes after switching on the power supply.
Buttons and display are always active during
parameterisation.
Starting parameterisation using the remote control is
possible at any time.
If the display is switched off, an activated output relay is
only shown on the display using the decimal point.
Output of the firmware version using 7-segment display:
Manual, each display point with
-
Automatic, in seconds cycle with the "i" key
-
The software version is, e.g.
1.10b-A_240406