List Of The Parameters For Adjusting The Relay Functionality - FEIG Electronic MWD BP-C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

P.
Setting
Function
range
O
0 ... 3
Object tracking
.
0 ... F
Output on delay
t
.
time
T
0 ... F
Output off delay
.
time
12

List of the parameters for adjusting the relay functionality

Parameter mode must be started before setting the parameters. The relay to be parameterised is selected
according to the following table depending on the device address.
FEIG ELECTRONIC GmbH
Manual
Description / note
A detected object can be tracked by the motion detector
even if it is moving very slowly. The sensitivity is specified
with this parameter.
0: off
1: low
2: medium
3: high
If this function is activated, minor movements such as,
e.g. leaves, rain or snow can cause continuous activation.
A relay activation delay time can be set for each of both
available channels.
0: 0 s
1: 0.2 s
....
F: 3.0 s
The respective value set is a multiple of 0.2 s.
The settings A to F correspond to the values 10 to 15.
A relay dropout delay time can be set for each of both
available channels.
0: 0 s
1: 0.2 s
....
F: 3.0 s
The respective value set is a multiple of 0.2 s.
The settings A to F correspond to the values 10 to 15.
Address
1 3 5 7 9 B D
Relay 1
1 3 5 7 9 B D
Relay 2
2 4 6 8 A C E
Page 40 of 103
MWD BP_Handbuch_mehrsprachig_12.doc
MWD BP
Factory
setting
0
0
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mwd bp-dMwd bp-u

Table des Matières