flash and a warning signal is emitted throughout the cycle
which may take from between 15 to 20 minutes.
RADIO TECHNICAL DATA:
•Frequency range 87÷108 MHz.
•Max. sensitivity 2,5µV-S/N 20dB.
•AFC automatic frequency control.
•Pu=5W RMS.
•D ≤10%.
•Muting.
•10-station memory.
•Last volume setting memory. Tuning memory; tuned to last
station at switch on.
Dismantling the shower valves:
In the event of the formation of lime scale and a resulting
malfunctioning of the shower valves, dismantle the parts
(fig. A/B/C...). We recommend you immerse the cartridge in
normal vinegar until it is completely lime scale-free.
To ensure correct operation of the thermostatic mixer,
the unit must be supplied from a boiler or a water heater
providing 6 to 7 litres per minute of water at a temperature
of 60/65°C.
INSTRUCTIONS FOR USE:
electrocution Hazard. Do not use electrical equipment of
any type inside the shower enclosure when the shower is
operating.
Massage functions:
FIXED SHOWER HEAD.
HYDRO-NECK.
HYDRO-BODY: for a total body massage concentrating on
the spinal column. Relieves back pain, tiredness and muscular
aches. Ideal for reducing physical stress.
Steam bath (optional):
Steam has been known since ancient times and today, thanks
to modern technology, can be enjoyed in every bathroom. A
hot, steam bath has a variety of benefits.
COSMETIC: steam heat opens the pores moisturising the
skin, making it smooth and soft.
HEALTH: steam increases perspiration helping the body to
eliminate toxins; it is also an effective anti-cellulite treatment.
The hot, steamy surroundings of a steam bath have a
beneficial, relaxing effect. A steam bath is best followed by
a hydromassage in the cubicle or in the bath to ensure the
complete elimination of toxins.
PRECAUTIONS:
Integrated cubicles will provide a variety of benefits if used
properly. You should observe the following precautions.
1) Do not exceed a maximum water temperature of 45°C.
2) Do not use the shower or the steam bath after a heavy meal
and while you are still digesting.
3) Do not exceed the maximum load of the seat (120 kg).
4) Children and the infirm should only use the cubicle under
the supervision of an adult.
5) Do not use the steam bath for longer than 20 to 30
minutes. Maximum permitted steam bath times vary with
age and body weight.
6) Persons with serious heart problems, high blood pressure
and acute illnesses should consult a medical practitioner
before using the steam bath.
7) SCALDING HAZARD. During a steam bath, keep your feet
away from the steam outlet nozzle.
CLEANING THE SHOWER UNIT:
CARING FOR YOUR CUBICLE
The cubicle panels are made of acrylic and must be cleaned
using a liquid detergent and a soft cloth or sponge. Use a
good quality household liquid detergent. To prevent scale
deposits, wipe dry using a chammy leather or a soft lint-free
cloth that removes stubborn deposits without leaving traces.
Limescale deposits may be removed using specific detergent
products. To restore shine to the acrylic surface polish with an
ordinary wax polish such as car wax. DO NOT USE ABRASIVE
CLEANERS, ALCOHOL OR ALCOHOL BASED PRODUCTS,
ACETONE OR OTHER SOLVENTS.
Liquid soap
TROUBLESHOOTING:
Before calling the Service Centre, check that:
• The hoses are properly connected and not kinked.
• Hot and cold water is being correctly delivered to the wall
fittings.
• The water supply system was bled before the shower unit
was installed.
• The mains power supply is reaching the steam generator
and the green Power On LED on the control panel is lit.
If you have followed the instructions and the shower still
does not work, call the nearest Service Centre. The telephone
numbers of authorised service centres are given in the
enclosed list.
WASTE DISPOSAL:
To dispose of the shower unit or any part of it, follow local
waste disposal regulations. In Italy, Legislative Decree No. 22
of 5 February 1997 applies. In other EU countries, the subject
is governed by directives 91/156/EEC, 91/689/EEC and 94/62/
EC.
EC DECLARATION OF CONFORMITY:
The manufacturer Opus Engineering S.r.l. via Mantova, 1023,
46030 Borgoforte (MN) Italy declares under its responsibility
that the Cubicles, equipped with steam generator mod. S
200/S 300 are in conformity with the following European
directives EEC 2006/99, EEC 2004/108 as amended EEC 92/31,
EEC 93/68 and with the following European standards:
(EN62233)
(EN55014-1)
(EN55014-2)
(EN60335-1)
(EN60335-2-15)
(EN61000-3-2)
(EN61000-3-3)
(EN61000-4-2)
(EN61000-4-3
(EN61000-4-4)
(EN61000-4-5
(EN61000-4-6)
(EN61000-4-11)