INSTALLATION INSTRUCTIONS
Step 1 - Preparation
Select the Outdoor location:
• Choose a level place solid enough to bear the
weight and vibration of the OD unit and where the
operation noise will not be amplified.
• Choose a location where the hot air
discharge and/or noise will not create a nuisance
for neighbors.
• Ensure there is sufficient space to maneuver the
OD unit into place.
• Ensure there is sufficient space and no
obstructions for the air inlet and outlet.
• Install the unit's power/communication wiring at
least 10 feet away from television and radio sets to
prevent interference.
• Ensure any moisture sensitive items are kept away
from the condensate drain path of the
OD unit.
NOTES:
• OD unit cannot hang from a ceiling or be stacked.
• Ensure that accumulated snow and debris will not
block the air inlet or the coil if installing the outdoor
unit with a fence or guard rail around it.
• Ensure ventilation in case of refrigerant leakage.
• Avoid installing the OD unit where corrosive gases,
such as sulfur oxides, ammonia, and sulfurous
gas are produced. Questions and product liabilities
pertaining to third party corrosion-proof or anti-rust
additives and the impact upon systems operation
should be directed to the manufacturers of those
products.
Step 2 - Installation of the Indoor Unit
Please refer to the Indoor unit installation manual.
16
Step 3 - Installation of the Outdoor Unit
A. Proper Installation for Drainage
Set the unit on mount or pad using team lift.
B. Prepare the Outdoor Unit for
Installation
• Remove all packaging.
• Place supplied vibration pads onto outdoor unit's
feet.
NOTE: Heat pump models may need a 3rd party
drain pan if condensate management is required
by local codes.
• Remove the cover plate of the outdoor unit to
expose the terminal block connections.
1. Remove Screw
2. Slide the panel down to
release the clips and pull
away.