Troubleshooti Ng - Zodiac Ei2 GenSalt OE Notice D'installation Et D'utilisation Succincte

Electrolyseur au sel
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

5. Troubleshooti ng

Ei²
Ei²Expert
GenSalt OE
INVERSION
"FLASH"
HIGH SALT
/
CHECK SALT
"Salt" indicator
on
NO FLOW
"Flow" indicator
on
CHECK PUMP • This message is displayed
/
PROD. ER-
ROR
/
OVERHEAT-
ING
/
All
/
setti ngs
lost
==> If the problem continues contact your retailer
14
Possible causes
The self-cleaning cycle is automati c;
this message is not an error code
but an informati on message.
• Salt overload (> 10 g/L).
• Lack of salt (< 3 g/L) due to water
loss or diluti on (fi lter backwash,
water renewal, rain, leaks, etc.).
• Pool water temperature too low
(< 18 °C, variable).
• Cell scaled up or worn.
• The fi lter pump has stopped or is
defecti ve.
• Presence of air or gas in the cell
(incorrect fi lling with water).
• By-pass valve(s) closed.
• Flow switch and/or cell
disconnected or defecti ve.
alternately with the "NO
FLOW" message if the situati on
conti nues.
• Short-circuit in the cell or cable
disconnected/badly connected.
• Worn electrode.
• Very low salt or no salt.
• Salt not yet suffi ciently diluted.
• Appliance internal temperature
over 70 °C.
• Appliance internal temperature
over +80°C.
• The appliance has stopped saving
the setti ngs (producti on level,
power, ti me, language, ti mers,
etc.)
.
Soluti ons
• Wait for about 10 minutes and chlorine
producti on will resume automati cally at
the previously set level.
• Parti ally drain the pool to reduce the salt
concentrati on.
• Add salt to the pool to keep the level at
4 g/l. If you do not know the salt level or
how to test it, consult your retailer.
• Basic producti on limitati on signal when
the water is too cold. Reduce chlorine
producti on or add salt to compensate.
• Clean or replace the cell.
• Check the pump and its programming
clock, the fi lter, the skimmer(s), and the by-
pass valves. Clean them if necessary.
• Check the wire connecti ons (cell and fl ow
switch).
• Check that the fl ow switch is working
correctly (replace it if necessary).
• Perform the same checks as above.
• Check the cell connecti ons.
• Replace the cell.
• Have the control box (printed circuit board
and transformer) checked by a qualifi ed
technician if necessary.
• Add salt to the pool to keep the level at 4
g/l.
• The appliance reduces its producti on to
50%.
• Producti on stops.
• Producti on restarts automati cally when the
temperature drops.
• Check the accumulator.
• Replace it if necessary (3V accumulator,
type "CR2032"), see "2.5.2 Connecti on
to an electric roller shutt er" to open and
close the box.
• Reprogramme the diff erent setti ngs in
the appliance, see "", "3.2.5 "SUMMER"
and "WINTER" modes and setti ng the
"Timers"", "3.2.6 "Internal setti ngs" menu".

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ei2 expert

Table des Matières