Automatic Shut-Off Feature - Bosch CS LD 1.0 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82
en |
40 | CS LD 1.0 | Operating Instructions
the trace on the display will rise
up as the concentration increases,
and rise down if the concentration
decreases.
Because the display in this mode
is based on a time period, the pre-
vious leak level sensed during this
time will be displayed, thus
ping the user to determine where
the maximum level of refrigerant is
present - thereby pinpointing the
source of the leak.
i i
The sensitivity level in this
mode will default to High, Re-
set Mode to Manual and Audio
to OFF; these settings cannot
be changed. To reset the graph
trace, press the Sensitivity
button; the reset arrow will
momentarily be shown. Once
reset, the trace will revert to
the baseline on the y-axis and
reset to the start on the x-axis.
Refer to Fig. 9 for an example
of leak tracing display.
|
F 002 DG9 H12
2021-04-08
hel-
Fig. 9:
Leak tracing display
6.6
Automatic shut-off
feature
The CS LD 1.0 includes an Auto
Shut-Off feature in order to preserve
battery life.
If the unit remains idle (i.e. no
alarm/change in sensor output) for a
period of 10 minutes, it will automa-
tically shut itself off.
Fig. 10:
Auto shut off display
Bosch Automotive Service Solutions GmbH
100%
M

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières