Dehumidification temperature
setting
(remote control temperature
setting + SHIDD)
30'
15'
(Limit time elapsed)
(Limit time elapsed) (Forcible operation)
(Limit time elapsed)
(Forcible operation)
(Forcible operation)
Fan speed set to AUTO
Fan speed set to AUTO
Fan speed set to AUTO
START/STOP switch
Operation lamp
Temperature judgment
Weak heating
Operation status
Weak heating
Heating dry
Room temperature category
Category 1
Category 2
Category 1
HI
MED
Indoor unit
LOW
SILENT
1'
2'
1'
15"
30"
Outdoor unit
1"
Latch-type reversing valve
1"
1'
Room two-way valve
Open
90"
90"
90"
WA R L OW 1
S T A R C P L
WARLOW1 ・ 2
WARLOW1 ・ 2
WAM D R Y 1 ・ 2 ・ 3
WA R L OW2
WA R L OW2
DMIN
Notes:
(1) The product determines the room temperature category and external temperature category as shown in Tables 1, 2, and 3 according to the room temperature and
external temperature, and performs control as shown in Tables 4 and 5.
(2) For the outdoor unit, its operation pattern is controlled as shown in Table 6 according to the room temperature category and external temperature category.
(3) If the operation status shown in Table 5 makes a state transition depending on the changes in room temperature or external temperature, the product will perform cycle
balancing with a compressor stop time as shown in Table 7.
(4) The operation time with the operation status in "weak heating" is up to 30 minutes. If the room temperature does not rise to room temperature category 2 after that time
limit has elapsed, the product will forcibly perform a "heating dry" operation for 15 minutes. (If the temperature does not rise to the room temperature setting, the product
will repeat "weak heating" and "heating dry.")
(5) When the external temperature ≧ 27℃, the operation in the heating region is inhibited. (The heating region will become a heating dry region.)
(6) When the temperature judgment is low humidity in room temperature category 2, the product will be stopped. (The compressor stop time at that time is 3 minutes or
more.) Provided that the product will not stop in clothes drying mode.)
(7) The temperature setting for dehumidifying operation must be set to the room temperature measured at the time of operation startup. Provided that the lower limit is 13℃
and the upper limit is 26 ℃. The fan speed is MED.
(8) The temperature setting for drying clothes must be the room temperature at the time of operation startup. Provided that the lower limit is 20℃ and the upper limit is 26℃.
The fan speed is HI.
(9) Dew control is operated in room temperature category 2 (WAMDRY1) only. The product will not stop even at low temperature. Weak heating will be activated at a room
temperature of 10℃ or less. The fan speed is MED.
(10) The humidity setting is about 50% in standard mode, about 40% in powerful mode, and about 60% in sleep mode.
(11) In room temperature category 2 or 3, the difference from the room temperature setting and humidity will cause the outdoor unit and compressor speed to be corrected
between C and J as shown in Table 6. Provided that, if the external temperature ≧ 29℃, the lower limit will be H.
(12) If the product is stopped in "heating dry" or "cooling dry," the outdoor unit will run for 30 seconds with the outdoor unit pattern J.
Downloaded from
www.Manualslib.com
Dehumidifying operation
Room Temperature
3 0 '
1 5 '
(Limit time elapsed)
(Forcible operation)
High humidity
Cooling dry
Heating dry
Weak cooling
Heating dry
Weak heating
Category 2
Category 3
Category 4
Category 2
Category 1
1'
3'
1'
15"
30"
30"
15"
1"
1"
1'
1'
100'
COLMAX-COLMIN
1"
90"
90"
STPSPTM1 ・ 2 ・ 3
90"
90"
WARLOW1
WAMDRY1・2・3
WAMDRY1・2・3
WARLOW2
WAM D R Y 1 ・ 2 ・ 3
CO L D R Y
COLDR
manuals search engine
Table 1 Room temperature category
(at the time of operation startup)
Room temperature
(relative value from the
temperature setting)
+a℃
+b℃
DRLWT ℃
−
Low
High humidity
humidity
Heating dry
Heating dry
Category 2
Table 4 Control by room temperature category
Room
temperature
category
Category 4
30"
30"
Category 3
1"
Category 2
Category 1
90"
WAMDRY1・2・3
Table 6 Control pattern for the outdoor unit
3' minimum
Pattern
A
SS1
B
SS3
C
Lo
D
SS1
E
SS2
F
SS3
G
SS4
H
SS5
I
SS6
J
SS7
(T1=GFSTM1,T2=GFSTM2)
Table 2 Room temperature category
(during operation)
Room
Room temperature category
temperature
Room temperature
When the room
When the room
category
(relative value from the
temperature declines
temperature declines
When the room
temperature setting)
(when shifted from
(when shifted from
temperature rises
category 3)
category 4)
Category 4
Category 4
+a℃
Category 3
Category 3
+b℃
+1.0℃
Temperature setting
Category 2
Category 2
−1.0
℃
DRLWLT ℃
−
Category 1
Category 1
Table 5 Outdoor unit control (initial values) according to the room
temperature and external temperature
External temperature
Room two-
Latch-type
Room
Compressor speed
way valve
four-way valve
temperature category
Operation status
COLMAX
Fully
Cooling
open
position
Category 4
COLMIN
Outdoor unit
control pattern
Fully closed
Cooling position
COLDRY
WAMDRY3
Operation status
Fully
Cooling
Category 3
WAMDRY2
closed
position
Outdoor unit
WAMDRY1
control pattern
Fully open
Heating position
WARLOW1
Operation status
Category 2
Outdoor unit
control pattern
Operation status
Category 1
Outdoor unit
control pattern
The outdoor unit patterns I and J are used for correction.
Table 7 Stop times in a state transition of the
operation status
Compressor
Control sequence
State transition
stop time
4'
Weak cooling ⇒ heating dry
None
T1
Heating dry ⇔ cooling dry
None
4'
Cooling dry ⇒ weak cooling
T2
3 minutes
Heating dry ⇒ weak cooling
3 minutes
Heating dry ⇒ weak heating
3 minutes
Weak heating ⇒ heating dry
1 minute
Table 8 Relative values from the temperature setting
External temperature
External temperature
State
transition
<32℃
≧32℃
a
DRCLCHK1
DRCLCHK2
b
DRCDCHK1
DRCDCHK2
Note:
1. For the constants expressed in uppercase alphabet letters in the figure,
see the data in PWRITE-ZU.
– 111 –
Table 3 External temperature category
External temperature category
External
temperature
When the external
When the external
temperature rises
temperature declines
Category 4
29℃
27℃
Category 3
20℃
18℃
Category 2
10℃
8℃
Category 1
category
Category 1
Category 2
Category 3
Category 4
Weak
Weak
Weak
Weak
cooling
cooling
cooling
cooling
C
C
C
C
Cooling
Cooling
Cooling
Cooling
dry
dry
dry
dry
B
B
G
H
Cooling
Heating dry
Heating dry Heating dry
dry
A
A
F
H
Weak
Weak
Weak
Heating dry
heating
heating
heating
C
C
C
C