Télécharger Imprimer la page

Desa RCLP100V Manuel Du Propriétaire page 8

Les langues disponibles

Les langues disponibles

SERVICE PROCEDURES
SPARK TRANSFORMER
1. Remove base tray.
2. Locate and disconnect white, black, and
orange wires from spark transformer.
3. Remove two screws holding spark trans-
former to base. Remove sheet metal nuts on
transformer and install on new transformer.
Discard spark transformer.
4. Install new spark transformer. Position new
spark transformer in same manner as old
transformer.
5. Connect white, black, and orange wires to new
spark transformer. Connect wires to correct
terminals as noted in step 2.
6. Replace base tray.
Ignitor
Wire
Figure 10 - Removing Ignitor Wire from
IGNITOR
1. Remove motor, motor mount, and fan guard
(see Motor, page 6, steps 1 through 6) .
2. Remove orange ignitor wire from ignitor.
3. Remove ignitor mounting screw from rear
head using nut-driver or standard screwdriver
(see Figure 11).
4. Remove ignitor from rear head.
5. Install new ignitor. Attach ignitor to rear head
with ignitor mounting screw.
6. Attach ignitor wire.
7. Check gap between ignitor electrode and
target plate to 0.13"/0.15" (3.3/3.8 mm) (see
Figure 12).
8. Test for spark.
8
Downloaded from
www.Manualslib.com
Continued
Spark
Transformer
Spark Transformer
manuals search engine
WARNING: Make sure heater
is disconnected from propane
supply. Heater could ignite caus-
ing severe burns.
Plug into extension cord and watch for spark
between ignitor electrode and target plate.
9. Place motor, motor mount, and fan guard
into rear of heater shell (see Motor, steps 14
through 18, page 7).
www.desatech.com
103908-01E
loading