PRO-POINT 8306078 Manuel D'utilisateur page 10

Cle a chocs pneumatique
Table des Matières
Les langues disponibles

Les langues disponibles

v 2.4
TROUBLE
SHOOTING
If the tool does not functionproperly or if it ismissingparts,contactPrincess Auto Ltd.for a
solution.If unableto do so, havea qualifiedtechnicianservicethe tool.
Problem(s)
Tool runsat normal speed
but losespower under load.
Toolrunsslowly.Air flows
slightlyfromexhaust.
Tool will not run. Air flows
freelyfromexhaust.
Tool will not shut off.
s
Los
of poweror
erraticperformance.
10
1 in. dr Impact Wrench
Possiblecause(s)
Motor parts worn.
Motor parts iammed with dirt particles.
OR
Air flow blockedby dirt.
Air Flow Regulator is in the
closedposition
O-rings throttlevalve dislodged from
seat inlet valve.
Damageor excessive w earingof
internal parts.
Material buildup impeding
motor
vanes.
O-rings throttlevalve dislodged from
seat inlet valve.
Excessive drain on the air line. Moisture
or restriction in the air hose. Incorrect
sizeor typeof hoseconnectors.
Air compressorhas insufficientflow.
Fortechnical questionscall 1-800-665-8685
8306078
Suggestedsolution(s)
Have a qualified technician
replace worn parts.
Check air inlet filter
for blockage.
Operatetool in shortbursts.
Disconnect air supply.Free
motor by rotating drive shank
manually where applicable.
Repeat a boveas needed.If this
fails,bringto Princess A uto Ltd.
or to a qualified technician.
Open regulator to
correct position
Have a qualified technician
replace the O-ring.
Bring to Princess Auto Ltd.or a
qualified technician.
Clean internal mechanism.
Bring to Princess Auto Ltd.or a
qualifiedtechnician.
Check the air supply.Ensure
tool is connected to a 1/2 in.
I.D. or larger air hosewith no
kinks or restrictions and that the
fittingsare connected properly.
Ensure tool is connected
compressor w ith a ratedflow
that matches the tool.
to a