USE ANTISTATIC AIR HOSES. SHOULD AN ANTISTATIC AIR HOSE NOT BE
AVAILABLE, YOU MUST ATTACH THE UNIT TO A GROUND CONNECTION IN
ORDER TO ELIMINATE ANY STATIC ELECTRICITY.
You must always connect the equipment and all the elements involved in the work
process to a grounding connection to eliminate static electricity. Regularly verify (one
a week) its electrical continuity. If its resistance exceeds the recommended limits, it
must be fixed. An equipment unit without or with a faulty grounding connection may
make the installation dangerous.
The total derivative resistance must be <1 million Ohms (Ω).
Read and carefully apply all the information, instructions and safety measures given by the
manufacturer of the products to be used (products to be applied, solvents, etc.), as chemical
reactions, fire and/or explosions may occur. These may be toxic, irritant or noxious and in any
event are dangerous for the health and wellbeing of the user and the personnel around him (See
section on Health and Safety).
Mix, prepare and filter the product to be applied in accordance with the
manufacturer's instructions, ensuring that no foreign particles ruin the
quality of the finish and application. Should there be any doubt on the
purity of the product, its composition, etc., please contact your supplier.
Control the viscosity of the product to be applied by means of ELCOMETER
2435 Viscosity Kit.
Ensure that the lid and tank close perfectly, keeping
the parts that come into contact (tank and lid) free of
product.
Avoid moving the pressure pot or laying it on its side
with product inside
Leave minimum of 10 cm. Free between the product
and the lid.
BE CAREFUL ABOUT EXPLOSION!
Be sure to use pressure tank at less than max. fluid working pressure.
Use at more than max. fluid operating pressure can cause explosion of
pressure tank resulting in great danger. Securely connect hose to avoid
leak and looseness. If hose is disconnected during operation, hazardous
hose movement and paint ejection will cause severe bodily injury.
If the equipment is going to remain for a long time running empty, disconnect it from the general
air network.