ANOMALY
The fluid does not
come
out or
insufficient output
Unstable
fluid output
The safety valve
does not relieve at
the pressure value
set
NOTE: The symbol (*) means that before starting the procedure it is necessary to release pressure (see paragraph 9.1)
www.elcometer.com
CAUSE
Insufficient air
pressure
Blocked fluid
passages
Level of the fluid
in the container
too low
Fluid viscosity
too high
Insufficient
air pressure
Damaged pressure
gauge
Damaged or faulty
safety valve
Clogged safety valve
CHECK POINT
Insufficient
air source
pressure
Improper
adjustment of
the air pressure
regulator
Fluid passages
between the fluid
outlet joint and
the suction pipe
The two-way fluid
outlet valve is closed
Condensed fluid
accumulated on the
bottom of the
container
Fluid level
Fluid viscosity
Fluctuating
air pressure
Pressure gauge
reading
Incorrect relief
pressure
Incorrect relief
pressure
REMEDY
Maintain the air
supply pressure at a
suitable level, but less
than 7 bar (102 psi)
Adjust the air
pressure suitably
through the
regulator
Remove any
obstructions. (*)
Open the valve
Remove or mix well
The fluid filling
level must be higher
than the inlet
suction pipe. (*)
Dilute the fluid
suitably. (*)
Ensure sufficient air
pressure: eliminate
any other air con-
sumption that might
compromise the air
system
Replace. (*)
Replace. (*)
Clean with air or
replace (*)
EN
15