Situation
External button does not
work at all
External button does not
work as expected
Digital switching mode:
Device does not work in sync
with NMEA 2000 digital
switching
equipment
digital switching mode
Engine alarm mode:
Device does not get engine
data, built-in LED flashes
red every 2 seconds
Possible cause and correction
1. External button is connected incorrectly. See section III. 2.
2. Wiring issue. Check the button wiring for a short or a bad contact.
3. Button issue. Check the button with a tester.
1. Wrong mode. Check the current mode with an external button
(see Section IV) or the YD:MODE command (see Section V).
1. Wrong bank. Check that the NMEA 2000 digital switching equipment
has the same bank. Reconfigure the Device with the YD:BANK command
(see Section V).
2. You are using Maretron NMEA 2000 digital switching
in
equipment but the Maretron support is turned off. Turn
on Maretron support with the YD:MARETRON ON command
(see Section V).
3. You are using CZone NMEA 2000 digital switching equipment
but the CZone support is turned off. Turn on the CZone support
with the YD:CZONE ON command (see Section V).
1. No engine data in NMEA 2000 network. Check that engine data
is available on a NMEA 2000 network.
2. Wrong engine ID setting. Check and modify the engine ID setting
with the YD:ENGINE command (see Section V).