String format
YD:COOLANT [OFF |
0..600 0..600]
YD:TR_TEMP [OFF |
0 ..600 0..600]
YD:RPM [OFF | 0..20000
0..600]
YD:BOOST [OFF | 0..6553
0..600]
Examples
YD:COOLANT 300 60
YD:COOLANT OFF
YD:TR_TEMP 200 1
YD:TR_TEMP OFF
YD:RPM 3500 180
YD:RPM OFF
YD:BOOST 1000 0
YD:BOOST OFF
— 21 —
Description
Turns on event 4 «Over Temperature» when
coolant temperature is above the specified
temperature in Celsius (first parameter)
during
specified
(second parameter, 0 – turns on the event
immediately). Factory setting is OFF.
The same as above, but for transmission
oil temperature, turns on the event 6
«Transmission: Over Temperature».
Turns on the event 14 «Revolutions Limit
Exceed» when engine revolutions are above
the value specified in the first parameter
during
specified
(second parameter, 0 – turns on the event
immediately). Factory setting is OFF.
Turns on event 11 «High Boost Pressure»
when the absolute boost pressure in kPa
is above the value specified in the first
parameter during specified number of seconds
(second parameter, 0 – turns on the event
immediately). Factory setting is OFF.
Table 1 continued
number
of
seconds
number
of
seconds