String format
YD:RESET
YD:DEV [0..255]
YD:SYS [0..15]
YD:PGN <pgn> [interval
| OFF]
YD:MODE [MOB | DS |
ENGINE]
YD:PLAY [0..28]
YD:LED [0..28]
Examples
System commands
YD:DEV 0
YD:SYS 0
YD:PGN 126993 60000
YD:PGN 127501 2000
Commands available in all modes
YD:MODE MOB
YD:PLAY 1
YD:LED 1
— 18 —
Description
Reset all settings to factory values, including
installation description strings.
Sets NMEA 2000 device instance value
(0 - 255). Factory setting 0.
Sets NMEA 2000 system instance value
(0 - 15). Factory setting 0.
Sets the interval in milliseconds between
outgoing periodic NMEA 2000 messages.
The
default
setting
(PGN 126993) is 60000, for the Binary Status
Report (PGN 127501) is 2000 milliseconds.
Valid range is 50 – 60000, OFF or 0 values
turns off message transmission.
Sets the mode. Device will be rebooted after
two seconds. Factory setting is MOB. Note,
that NMEA 2000 device class and function
will be changed after reboot, and you may
need to refresh NMEA 2000 devices list in the
software.
Plays sound at specified number (1 – 28) or
stops playback (0). See Appendix B.
Runs indication sequence at specified number
(1 – 28) on external LED or stops indication
(0). See Appendix C.