General Safety Instructions; Intended Use - Dometic SeaLand DVF1619 Mode D'emploi

Filtre de purge d'air
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Dometic Vent Filter
2

General safety instructions

The manufacturer will not be held liable for claims for damage resulting from the following:
• Faulty assembly or connection
• Damage to the unit from mechanical influences
• Alterations to the unit without express written permission from the manufacturer
• Use for purposes other than those described in the operating manual
3

Intended use

When a toilet is flushed on a boat with a holding tank, air is pushed out of the holding tank, through
a vent hose, and out of the boat through a vent fitting . To stop foul-smelling air from coming out of
the vent fitting, install a Dometic Vent Filter .
4
Installation
Remove old filter
(if replacing existing vent filter)
1 . Remove vent hose from both ends of old vent filter .
2 . Remove old filter from bracket and seal ends with caps that are provided with new filter .
3 . Discard old filter in appropriate container .
Install new filter
1 . Select location for vent filter . Avoid areas near excessive heat sources (engine manifolds, lights, etc .) .
Do not install filter below top of holding tank (fig .
2 . Vent filter can be mounted at any angle . Installations near thru-hull vent reduce chance of filter
damage from potential overfilling of tank .
3 . Install mounting bracket (fig .
4 . Press vent filter (fig .
5 . Install 5/8-inch or 3/4-inch (16 mm or 19 mm) hose adapters (fig .
filter, making sure rubber gaskets (fig .
hand tight .
6 . Using hose clamps (fig .
(5/8-inch or 3/4-inch) I .D . vent hoses (fig .
(fig .
3
1, page 2) to hose adapters on filter .
Caution!
Do not use Dometic
board sewage treatment systems that use chlorine or other strong oxidizing agents .
Caution!
Replace vent filter immediately if accidental overflow of holding tank occurs.
Note
Replace vent filter at the beginning of each boating season for best odor control .
2
1, page 2) with fasteners (fig .
3
6, page 2) into mounting bracket .
3
3
3, page 2) (not included with vent filter), install 16 mm or 19 mm
Vent Filter for holding tanks with waste that is treated through on-
®
1
page 2) .
5, page 2) are in place . Tighten 1/4 to 1/2 turn beyond
3
2, page 2) from holding tank and thru-hull fitting
General safety instructions
2
2, page 2) .
3
4, page 2) on both ends of
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dvf1619

Table des Matières