Technical Datas - Adeunis RF HCA-UNITY1 Mode D'emploi

Répartiteur de frais de chauffage
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ADEUNIS RF HCA - USER GUIDE - V1.2

5. Technical datas

Standards
Principle of measurement
Type of sensor
Operating temperature limits 35°C/95°C for 2F version
Max storage conditions
Dimensions
Power supply
Operating life time
Display
Scaling
Delivery
Operation
Tamper recognition
Failure detection
Water fluid radiator
Measuring cycle
Memory
RF interface
RF Data Encryption
Radio Characteristics
Degree of protection
Approval
EN834-ed2013, EN13757-4, EN300-220
2 integrated sensors : 2F version
1 integrated sensor & 1 remote sensor : FF versions
NTC sensor with 0.5% accuracy in range 0 to 90°C
35°C/105°C for FF version
-25°C/60°C
High 78mm / Width 38mm / Thickness 30mm
3V0 – DC supply lithium battery
10 Years + reserve
6 digits LCD
Unity scale
Park mode (measuring and display not active)
Automatic start up 10 seconds after mounting on heat conductor
Mechanical seal + Electronic opening detection.
Sensors function, Low battery, Fraud tentative.
Up to 10000W power
Each 4 minutes
Last 15 months consumption values
OMS Wireless MBUS protocol. S1, T1 modes according to EN13757-4
AES 128 Mode 5
Power emission : up to 12 dBm
Frequency : 869 MHz
According to EN300-220
IP41
German HKVO approved, file register C3.01.2014