WARNING • To comply with the National Electric Code and Underwriters Laboratories requirements, the edge of the wall
plate coming in contact With the mounting surface must be sealed with a latex waterproof caulking to prevent water from
entering the outlet box.
WARNING - If any Speaal Control Devices are used with this Fixture, Follow the Instructions Carefully to assure full
compliance
with N.E.C. requirements.
WARNING
- This product contains
other reproductive harm. Thoroughly wash hands after Installing, handling, cleaning, or otherwise touching this product.
6
1
3
2
1.— Fasten Mounting
Strap (3) to Outlet Box (I)(NOT
2.— Thread
Nipple
(5) and Green Ground Screw (9) into
3.— Connect Fixture
Wires (4) to Supply Wires (2) as shown in Wiring
Slip Cage Assembly (7) over Nipple
5.— Place Glass Panels (11) into
6.-
Install
Lamp (NOT FURNISHED).
Assembly & Installation
CAUTION:
Read instructions
circuit
5759,
If there are any questions,
chemicals
known to the State of California
4
9
5
FURNISHED) with Mounting
(5) and secure in place with
Cage Assembly
(7) and bend Top and Bottom
carefully
breaker panel before beginning installation.
5760
contact a Qualified
to cause cancer, birth defects and /or
7
10
11
10
8
Mounting
Strap (3).
Diagram.
Capnut (8).
Tabs (10) against
PAGE
1
Instructions
and turn electricity
Electrical Contractor.
WHITE SUPPLY
WHITE OR IOENTIFIEO
WIRE
FIXTURE
BLACK
SUPPLY
PLAIN
WIRE
FIXTURE
BARE, OR GREEN
BARE, OR GREEN
GROUND
WIRE
F XTURE
FROM
SUPPLY
OR
BARE, OR GREEN
GROUND
WIRE
FROM
SUPPLY
(NOT FURNISHED)
(NO INCLUIDA)
(NON FOURNIE)
Screws (6) from
Outlet
Box (1).
Glass to secure.
SPEC.NO.
023790
off at main
WIRE
UL LISTED
WIRE NUTS
OR BLACK
WIRE
GROUND
WIRE
GREEN
GROUND
SCREW
02-11-09
loading

Sommaire des Matières pour Progress Lighting 5759

  • Page 1 5759, 5760 WARNING • To comply with the National Electric Code and Underwriters Laboratories requirements, the edge of the wall plate coming in contact With the mounting surface must be sealed with a latex waterproof caulking to prevent water from entering the outlet box.
  • Page 2 Instrucciones ensamblado instalacion PRECAUTION. Antes de comenzar la instalacion, lea las instrucciones • detalladamente y desconecte la electricidad desde el cortacircuitos principal. ADVERTENCIA - Para cumphr con el codigo Electrico Nacional y los requistos de los Laboratonos Underwriters, para instalacioes al exterior o en sitios humedos, es necesario que el borde de la placa de pared que toca la superficie...