5. Operation

5.2. Mode select

Press the operation mode (
tion mode
.
2
Cooling mode
Drying mode
Fan mode
Heating mode
Automatic (cooling/heating) mode

Automatic operation

According to a set temperature, cooling operation starts if the room tem-
perature is too hot and heating operation starts if the room temperature
is too cold.
During automatic operation, if the room temperature changes and re-
mains 1.5°C, 3°F or more above the set temperature for 3 minutes, the
air conditioner switches to cooling mode. In the same way, if the room
temperature remains 1.5°C, 3°F or more below the set temperature for
3 minutes, the air conditioner switches to heating mode.
Cooling mode
3 minutes (switches from
heating to cooling)
3 minutes (switches from cooling
to heating )
Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed a
few degrees warmer and heating operation is performed a few degrees
cooler than the set room temperature once the temperature is reached
(automatic energy-saving operation).

5.3. Temperature setting

To decrease the room temperature:
Press
button
to set the desired temperature.
3
The selected temperature is displayed at
To increase the room temperature:
Press
button
to set the desired temperature.
3
The selected temperature is displayed at
• Available temperature ranges are as follows:
Cooling/Drying:
19 - 30°C, 67 - 87 °F
Heating:
17 - 28°C, 63 - 83 °F
Automatic:
19 - 28°C, 67 - 83 °F
• The display blinks either 8°C - 39°C, 46°F - 102°F to inform you if the
room temperature is lower or higher than the displayed temperature.
5.4. Fan speed setting
Press the Fan Speed button
5
system is running.
• Each press changes the force. The currently selected speed is shown
at
.
5
• The change sequence, and the available settings are as follows.
FAN SPEED
Speed 1
Speed 2
4-speed
+
Auto *
Speed 1
3-speed
+
Auto *
Speed 1
4-speed
model
* For MA remote controller only.
Automatic fan speed setting is necessary for wireless remote controller.
) button
and select the opera-
2
Set temperature +1.5°C, +3°F
Set temperature
Set temperature -1.5°C, -3°F
.
3
.
3
as many times as necessary while the
Display
Speed 3
Speed 4
Speed 2
Speed 3
Auto
Speed 2
Speed 3
Speed 4
Note:
The number of available fan speeds depends on the type of unit connected.
Note also that some units do not provide an "Auto" setting.
In the following cases, the actual fan speed generated by the unit will differ
from the speed shown the remote controller display.
1. While the display is showing "STAND BY" or "DEFROST".
2. When the temperature of the heat exchanger is low in the heating mode.
(e.g. immediately after heating operation starts)
3. In HEAT mode, when room temperature is higher than the temperature
setting.
4. When the unit is in DRY mode.
Automatic fan speed setting (For wireless remote controller)
It is necessary to set for wireless remote controller only when auto-
matic fan speed is not set at default setting.
It is not necessary to set for wired remote controller with automatic
fan speed at default setting.
1 Press the SET button with something sharp at the end.
Operate when display of remote controller is off.
blinks and Model No. is lighted A
MODEL SELECT
2 Press the AUTO STOP
blinks and setting No. is lighted B
(Setting No.01: without automatic fan speed )
3 Press the temp.
(Setting No.02:with automatic fan speed )
If you mistook the operation, press the ON/OFF
ate again from procedure 2.
4 Press the SET button with something sharp at the end.
and Model No. are lighted for 3 seconds, then turned off.
MODEL SELECT
5.5. Airflow direction setting
<To Change the Airflow's Up/Down Direction>
With the unit running, press the Airflow Up/Down button
• Each press changes the direction. The current direction is shown at
• The change sequence, and the available settings, are as follows.
Airflow
5 steps
model*1
4 steps
model
Auto
* Note that during swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
* Some models do not support directional settings.
*1. For MA remote controller only, other remote controllers display the same
as 4 steps model.
*2. PKFY-P·NBMU-E2 has no swing display.
*3. Airflow direction setting <Auto>
COOL / FAN / DRY: Setting 1 (Horizontal), HEAT: Setting 5 (Downward 5)
.
button.
.
buttons to set the setting No.02.
B
MODEL SELECT
A
ON/OFF
TEMP
3
FAN
AUTO STOP
2
MODE
VANE
AUTO START
CHECK
LOUVER
h
TEST RUN
min
SET
RESET
CLOCK
14
Display
Swing
Auto
1
2
3
Swing
1
2
3
(Horiz.)
button and oper-
as necessary.
6
.
6
4
5
4
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

City multi pkfy-nhmu-e2City multi pmfy-nbmu-e

Table des Matières