Air Filter/Regulator and Pressure Switch Replacement
12. Locate the new brass coupler (015550) and pipe fitting (015618) in the kit.
13. Lightly apply thread sealant to the threads on one end of the pipe fitting, and screw the coupler onto that end of the
pipe fitting.
14. Apply a small drop of thread sealant to the threads on the other end of the pipe fitting, and screw that end of the
fitting into the side of the air filter/regulator.
If applied too heavily, excess amounts of thread sealant can contaminate the gas line.
Coupler
The regulator is pre-set at the factory. Do not adjust this setting.
8
Pipe fitting
CAUTION!