Télécharger Imprimer la page

Hypertherm Powermax30 Mode D'emploi page 7

Bulletin de service sur le terrain; remplacement du filtre à air et du détendeur
Masquer les pouces Voir aussi pour Powermax30:

Publicité

10. Unscrew the retainer nut that holds the air filter/regulator in the bracket.
11. Tip the bottom of the air filter/regulator and pressure switch assembly away from the power supply, and slide the
assembly out of the bracket. Gently tilt the top of the rear panel away from the power supply as you remove the
assembly, if needed.
1
Retainer nut
Center panel bracket
2
Powermax30/30 XP Field Service Bulletin 805330 Revision 2
Air Filter/Regulator and Pressure Switch Replacement
1
2
3
3
Air filter/regulator
7

Publicité

loading

Ce manuel est également adapté pour:

Powermax30 xp