Introduction
Purpose
This Field Service Bulletin describes the necessary steps to replace the air filter/regulator and pressure switch assembly
on Powermax30 power supplies.
This kit contains separate air inlet fittings for the Powermax30 and the Powermax30 XP. The fittings for the
Powermax30 XP will not work on the Powermax30 because they are too large to fit through the rear panel.
Powermax30 XP systems: Complete instructions for installing this repair kit are included in the Powermax30 XP
Service Manual (808150). To download the Service Manual, go to
library" link.
Tools and materials needed
Assorted Phillips
®
and TORX
1/2 inch wrench or adjustable wrench (CSA models only)
19 mm wrench or adjustable wrench (CE models only)
Thread sealant
Never use PTFE tape on any joint preparation. Use only a liquid or paste thread sealant on male
threads.
Powermax30/30 XP Field Service Bulletin 805330 Revision 2
Air Filter/Regulator and Pressure Switch Replacement
Disconnect electrical power before performing any maintenance.
See the Safety and Compliance Manual (80669C) for more safety
precautions.
®
screwdrivers
WARNING!
ELECTRIC SHOCK CAN KILL
www.hypertherm.com
CAUTION!
and click the "Downloads
3