6.
Mounting the appliance
6.1

Application

One appliance can be used for the following applications:
One or multiple hand washing sinks
One kitchen sink
Cabins with flow restriction at shower head.
A combination of two appliances can be used for whole apartment
and house applications. Please contact STIEBEL ELTRON for special
installation instructions.
All areas with a ground water temperature likely to exceed 65 °F
(18 °C) year round:
Whole apartment or house
CAUTION: Electrocution
Unit must be installed in a vertical position with the
water fittings pointing downward. In this position the
unit is splashproof, so that no water can soak in.
1
7
2
1
3
4
7
5
6
1 Hot valve (left)
2 Cold valve (right)
3 Sink
4 ½˝ main pipe
5 Water supply line for faucet installation
6 Shut-off valve
7 Electrical junction box
6.2

Mounting

Install appliance as close as possible to the main hot water
draw-off points.
Install appliance in a frost free area. If frost may occur, re-
move appliance before freezing temperatures set in.
Leave a minimum of 5˝ (125 mm) of clearance on all sides for
servicing.
www.stiebel-eltron-usa.com
2
3
4
5
6
Remove plastic cover.
Screw the screws into the wall and hang the appliance.
Screws and plastic wall anchors for mounting on masonry or
wood are provided.
Secure the screws.