TROUBLESHOOTING
Failure
Trouble
1. Fuel tap is in "OFF" position.
2. Lack of fuel.
Inventor
3. Lack of engine oil.
generator fails
to start.
4. Spark plug is splashed by fuel.
5. No ignition.
Engine runs
1. Short circuit in a connected
well at no-
load.
load, but bogs
2. Generator is overloaded.
when load is
3. Engine speed is too slow.
applied.
4. Shorted generator circuit.
1. Out of fuel.
Engine shuts
2. Low oil level.
down during
3. Fault in engine.
operation.
4. Temperature is too high.
1. Breaker trip.
Generating set
2. Inadequate cord sets or
has no output.
extension cords.
1. Load is too high.
Engine lacks
2. Dirty air filter.
power.
3. Engine needs to be serviced.
1. Fuel tap is in OFF position.
2. Dirty air filter.
3. Out of fuel.
4. Stale fuel.
Engine will not
5. Spark plug wire not connected
start; or starts
to spark plug.
and runs rough.
6. Bad spark plug.
7. fuel is mixed with water.
8. Low oil level.
9. Excessive rich fuel mixture.
10. Engine lost compression.
1. Circuit breaker OPEN.
Engine is
2. Poor connection or defective
running, but
cord set.
AC output is
3. Connected device is bad.
not available.
4. Fault in generator.
5. The AC outlet cable is loosen.
Solution
1. Rotate the fuel tap to "START" position.
2. Fill fuel tank per instructions in this manual.
3. Check oil level. Add recommended oil if the oil level is low.
This engine is equipped with a low oil sensor. The engine
cannot be started unless the oil level is above the prescribed
lower limit.
4. Remove the spark plug and wipe the fuel.
5. Remove the spark plug cap.Clean any dirt around the plug
base, and then remove the spark plug. Install the spark plug
in the plug cap. Turn the engine switch to "START"
position. Grounding the electrode to any engine ground, pull
the recoil starter to see if sparks jump across the gap. If there
is no spark, replace the plug.Reinstall the plug and start
engine according to instructions in this manual.
1. Disconnect shorted electrical load.
2.Check your generator limits. Press the overload protector off
and reduce loads.
3. Turn off the ECO switch and try again.
4. Consult Customer Service.
1. Fill recommended fuel to fuel tank.
2. Fill recommended oil to correct level.
3. Consult Customer Service.
4. Wait for temperature reduced and restart the generator.
1. Reset circuit breakers.
2. Check cord sets or extension cords capabilities in section
controls; check cable size in this manual.
1. Reduce load (see Know Generator Limits ).
2. Clean or replace air filter.
3. Contact IASD. Maintenance your generator.
1. Turn fuel tap to ON position.
2. Clean or replace air filter.
3. Fill fuel tank.
4. Drain fuel tank and fill with fresh fuel.
5. Connect wire to spark plug.
6. Replace spark plug.
7. Drain fuel tank and fill with fresh fuel.
8. Fill crankcase with recommended oil to correct level.
9. Contact IASD.
10. Contact IASD.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in good condition.
4. Contact Customer Service.
5. Remove the panel cover and connect the cable. It should be
done with a qualified electrician.
23