5.2
DISPLAY OPERATION
5.2.1
SWITCHING ON THE APPLIANCE
At the first switch-on, the appliance shows the factory settings. Every time it is
switched on after that, it will show the last settings used.
At switch-on, the display uploads the firmware and prepares for the dispensing phase.
5.2.2
DOSE DISPENSING AND ADJUSTMENT
• After positioning the portafilter/ground coffee container (6) on the fork, select the dose to
be dispensed by pressing the single dose (14)
relative button will light up).
• During dispensing, the display shows the value of the measured weight until the set
value is reached.
• During dispensing, the single or double dose button will flash.
ATTENTION
The selected dose button remains enabled for 10 seconds after the portafilter/
ground coffee container has been positioned. If you wait more than 10 seconds
before pressing the button, grinding will not begin and the display will show the
code "FH". To re-enable grinding, take the portafilter out and then insert it again.
ATTENTION
If the portafilter/ground coffee container is not inserted correctly, grinding will
not begin when the button is pressed and the display will show the code "FH". To
re-enable grinding, take the portafilter/ground coffee container out and then insert
it again.
ATTENTION
Grinding only begins once the portafilter/ground coffee container (or another
container) has been inserted on the portafilter fork.
• When dispensing has ended, the dose grinding grammes return to the set value and
the counter value increases by the quantity of grammes ground.
• Press buttons (13)
envisaged for the dose selected (the weight is shown in grammes on the display).
The increase/decrease is made in steps of one tenth of a gramme.
and (14)
to reduce or increase the coffee weight
or double dose (15)
button (the