There should be at least 50 mm between the wall of non-combustible material and
the stove.
Safety distances can be reduced by using protective screens made of
non-combustible material. The single-layer light protective screen allows to reduce
the safety distances by 50% and the double light protective screen by up to 75%.
The protective screen is included in the safety distance, which means that the
distance is measured to the flammable material, not to the protective screen. There
should be a gap of at least 50 mm between the protective screen and the sauna stove.
The safety distance between the sauna stove and the ceiling can be reduced by
25% by using the single protective screen. The double protective screen is not
used in the ceiling.
The single light protective screen is made of at least 7 mm thick non-combustible,
fibre-reinforced cement board or of at least 1 mm thick metal plate, which is firmly
attached to the wall. An air gap of at least 30 mm should remain between the surface to
be protected and the protective screen.
The double protective screen can be made of the same materials as mentioned above.
There should be an air gap of at least 30 mm between the protective screen and
the wall. There should be an air gap of at least 30 mm between the protective screen
and the floor and ceiling to ensure adequate air circulation.
ATTENTION!
Before reducing the safety distance, please check the local safety
laws and regulations in your country.
When installing flues, the safety distances specified in the instruction manual of the
respective manufacturer should be followed.
To protect flooring made of combustible material in front of the sauna stove, the sheet
metal plate should be attached to the floor in front of the stove, which extends at least
100 mm beyond the sides of the door opening of the stove, and at least 400 mm in front
of the stove. The edge of the plate closest to the stove side should be bent up so that the
coal falling from the sauna stove does not get under the stove. Information on HUUM floor
protection plate (sold separately) has been provided in Appendix 5, page 30.