BASE SURFACE
The sauna stove is installed in the sauna room to the floor of non-combustible material
with sufficient load-bearing capacity. The concrete floor with the thickness of at least
50 mm is suitable.
If the floor heating cables or pipes are located under the sauna stove, the thermal
plate for HUUM sauna stoves or other non-combustible material and additional
protection with sufficient thickness and load-bearing capacity should be used to
protect these from heat radiation. The information on HUUM thermal plate has been
provided in Appendix 5, page 30.
In case of the floor made of combustible material, it is mandatory to use the thermal
plate for HUUM sauna stoves or some other non-combustible material and additional
protection with sufficient thickness and load-bearing capacity. The ventilation gap of at
least 30 mm is mandatory between such a base and the floor, so that air can move freely.
SAFETY DISTANCES
A
Figure 7. Safety distances of HIVE Flow sauna stove from flammable materials
(e.g. wooden wall, bench etc).
Table 1.
Flow
Flow LS
Flow Mini
Flow Mini LS
8
C
A
Room
Weight
m
kg
3
8-18
67
8-18
73
6-14
54
6-14
59
Min. 1000
A
Quantity of
A
stones
mm
kg
150
150
150
150
105
150
105
150
B
C
B
mm
mm
500
826
500
826
500
750
500
750